Seaward Group USA
The range of resistance decade boxes includes 5, 6 and 8 decade boxes which are designed to provide highly accurate and variable standard values of resistance and current for calibration, comparison and test applications in electrical and electronic workshops, test laboratories and educational environments
-
Elcometer Limited
Supplied with either standard cables or armoured metal reinforced heavy duty cables, Elcometer convex surface profile probes are supplied with a glass zero tile, calibration test foils (nominal values 125μm (5.0mils) & 508μm (20mils)) and an Elcometer test certificate.
-
85052C -
Keysight Technologies
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
ADC-1000 -
TestVonics, Inc.
The ADC-1000 is a high precision Air Data Monitor that can be used as to precisely measure pressures. It can also be used as a transfer standard. The ADC-1000 can be used to verify standards without having to ship them out for calibration. TestVonics also offers an Air Data Transfer program to customers, allowing them to calibrate equipment in-house. This helps prevent damage to equipment in transit, which can be costly and increase organizations downtime.
-
1395D -
Ballentine Laboratories, Inc.
The 1395D series of TVC's, have Dual Thermal Element technology. The 1395D offers double the output voltage (typically 14 mV instead of 7 mV). This higher output voltage means better resolution and increased accuracy. It can be used to measure AC Voltages between 20 Hz and 100 MHz and it can serve as a primary AC voltage standard and/or standard for calibration of AC calibrators and voltmeters.
-
RS-933 -
Radian Research, Inc.
The RS-933 Syntron Power and Energy Automated Calibration System calibrates a range of test equipment including; Energy Reference Standards, Digital Multimeters, Phase meters, Energy meters, Power meters, Revenue meters, Amp meters, Panel meters & Power Quality meters.
-
Spectrum Elektrotechnik GmbH
Vector Network Analyzers are commonly used to accurately determine the RF Characteristics of microwave components. Accurate Testing of microwave circuits means eliminating measurement errors and ensuring repeatable results. This is only possible when the network analyzers can be calibrated with known and true calibration standards.
-
8487D -
Keysight Technologies
Excellent SWR for reducing mismatch uncertainty Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 50 MHz to 50 GHzDiode power sensing element
-
MicroSafe 500 & 600 Series -
Teledyne Gas & Flame Detection
MicroSafe 500 and 600 Series gas detectors feature a non-intrusive operator interface. Calibration and programming instructions appear in simple intuitive and sequential script on a 16-character backlit display. The transmitter design incorporates extensive fault diagnostics with each condition conveniently identified on the transmitter display.The 500 Series comes standard with a linear 4-20 mA output, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault and calibration status.The 600 Series includes the same features as the 500 with the addition of 3 alarm relays and an RS-485 serial communications port.Electrical Classification - Explosion proofClass I, Div 1, Groups B, C, D
-
ES500 -
ETAS GmbH
ETAS makes the entire software and hardware range available from program development to the calibration of your ECUs. You can use the ETAS tools to address all ECUs that satisfy the ASAM standard. By using these standardized interfaces, our tools are not limited to the ECUs of any particular manufacturer.
-
85032E -
Keysight Technologies
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Power Diagnostix Systems GmbH
Power Diagnostix calibrators enjoy all the advantages of 20 years' experience in calibration services. The broad range of easy-to-use and robust units for many different applications ensures reliable PD measurements compliant to international standards, such as IEC 60270, CISPR 18-2, and NEMA 107-1987.
-
MC142 -
Powertek LLC
Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.
-
AE Techron, Inc.
Easiest-to-use LF wave sequence generator1550+ automotive and aviation standards' tests includedDramatically reduces test time for repetitive test sequencesSemi-automatic calibration routine significantly reduces labor-intensive tasks (like CS101)Very easy to modify included waveform sequences or create new ones
-
Quartzlock (UK) Ltd.
The Quartzlock range of distribution amplifiers are intended for use when multiple outputs from a single frequency standard/generator are required. This may be encountered in engineering labs, national standards labs, research and development, calibration labs and production. This is vital for the distribution of signals from other precision frequency standards like Hydrogen Masers, Cesium oscillators. For a technical discussion about distribution amplifiers go here or select a product range below.